{"_buckets": {"deposit": "87ed48da-c7d6-42a9-a097-e81b29926983"}, "_deposit": {"created_by": 4, "id": "1168", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "1168"}, "status": "published"}, "_oai": {"id": "oai:nipr.repo.nii.ac.jp:00001168", "sets": ["373"]}, "author_link": ["289", "280"], "item_1_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1981-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "61", "bibliographicPageStart": "49", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "Memoirs of National Institute of Polar Research. Special issue"}]}]}, "item_1_creator_8": {"attribute_name": "著者名(英)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamanouchi, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "280", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wada, Makoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "289", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_type": "Other"}]}, "item_1_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "Spectral measurement of direct solar radiation was made by a spectrometer on the ground, and the total amount of water vapor was estimated. The result was 0.09g/(cm)^2 at least in April and 0.16g/(cm)^2 at most in December. In the present work, 0.9μm near infrared absorption band of water vapor was measured in a rather low resolution and the total absorption was obtained. Using the relation of the water vapor amount and the total absorption (curve of growth), the water vapor amount was derived from the measured total absorption. Uncertainties in the 100% transmission line and uncertainties in deriving the column amount of water vapor for the actual inhomogeneous distribution from the equivalent amount, resulted in errors. Since the measurement was made at Mizuho Station and there was no aerological data for comparison, the data of radiosonde flight at Syowa Station was compared. Efficiency of the present result and the method to obtain the column amount of water vapor were discussed.", "subitem_description_type": "Other"}]}, "item_1_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00733561", "subitem_source_identifier_type": "NCID"}]}, "item_1_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "National Institute of Polar Research/National Institute of Polar Research"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "1981-10-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00000011694.pdf", "filesize": [{"value": "1.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_6", "mimetype": "application/pdf", "size": 1400000.0, "url": {"label": "KJ00000011694", "url": "https://nipr.repo.nii.ac.jp/record/1168/files/KJ00000011694.pdf"}, "version_id": "b51a5da6-99f3-42ff-a79f-d12d763b7615"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "On the Spectrometer Measurements of Column Water Vapor Amount in the Antarctic Atmosphere", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "On the Spectrometer Measurements of Column Water Vapor Amount in the Antarctic Atmosphere", "subitem_title_language": "en"}]}, "item_type_id": "1", "owner": "4", "path": ["373"], "permalink_uri": "https://nipr.repo.nii.ac.jp/records/1168", "pubdate": {"attribute_name": "公開日", "attribute_value": "1981-10-01"}, "publish_date": "1981-10-01", "publish_status": "0", "recid": "1168", "relation": {}, "relation_version_is_last": true, "title": ["On the Spectrometer Measurements of Column Water Vapor Amount in the Antarctic Atmosphere"], "weko_shared_id": 4}
On the Spectrometer Measurements of Column Water Vapor Amount in the Antarctic Atmosphere
https://nipr.repo.nii.ac.jp/records/1168
https://nipr.repo.nii.ac.jp/records/1168f94d0a77-b445-4817-a3f3-58e9ec89cedb
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00000011694 (1.4 MB)
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1981-10-01 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | On the Spectrometer Measurements of Column Water Vapor Amount in the Antarctic Atmosphere | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
著者名(英) |
Yamanouchi, Takashi
× Yamanouchi, Takashi× Wada, Makoto |
|||||
著者所属(英) | ||||||
en | ||||||
National Institute of Polar Research/National Institute of Polar Research | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Spectral measurement of direct solar radiation was made by a spectrometer on the ground, and the total amount of water vapor was estimated. The result was 0.09g/(cm)^2 at least in April and 0.16g/(cm)^2 at most in December. In the present work, 0.9μm near infrared absorption band of water vapor was measured in a rather low resolution and the total absorption was obtained. Using the relation of the water vapor amount and the total absorption (curve of growth), the water vapor amount was derived from the measured total absorption. Uncertainties in the 100% transmission line and uncertainties in deriving the column amount of water vapor for the actual inhomogeneous distribution from the equivalent amount, resulted in errors. Since the measurement was made at Mizuho Station and there was no aerological data for comparison, the data of radiosonde flight at Syowa Station was compared. Efficiency of the present result and the method to obtain the column amount of water vapor were discussed. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00733561 | |||||
書誌情報 |
Memoirs of National Institute of Polar Research. Special issue 巻 19, p. 49-61, 発行日 1981-10 |