{"created":"2023-07-25T11:05:37.657678+00:00","id":8943,"links":{},"metadata":{"_buckets":{"deposit":"caf0a695-8e2a-4ed5-8757-89758b628c49"},"_deposit":{"created_by":4,"id":"8943","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"8943"},"status":"published"},"_oai":{"id":"oai:nipr.repo.nii.ac.jp:00008943","sets":["1259:906:1235:1115"]},"author_link":["4247","12247","65759","65760"],"item_1_alternative_title_5":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_alternative_title":"ヒョウショウ コア カイセキ ノ タメノ ECM ゾウフクキ ノ カイリョウ ト データ ショリ"}]},"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"313","bibliographicPageStart":"307","bibliographicVolumeNumber":"40","bibliographic_titles":[{"bibliographic_title":"南極資料"},{"bibliographic_title":"Antarctic Record","bibliographic_titleLang":"en"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大井, 正行"},{"creatorName":"オオイ, マサユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"成田, 英器"},{"creatorName":"ナリタ, ヒデキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_1_creator_8":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ohi, Masayuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Narita, Hideki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_11":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_description":"これまで使用されてきたECM(Electric Conductivity Measurement)装置の電流増幅器の部分の改良を行った。主な改良点は, 電流増幅器の性能向上による雑音の逓減とフローテング回路を採用し, あらゆる点の絶縁性をよくしたことである。その結果, 同じ場所での数回の測定に対して再現性のよいデータが得られた。このデータは, また, パソコンで即時処理されるようにした。","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"An ECM (Electric Conductivity Measurement) apparatus was improved by reconstructing the current meter amplifier. The main improvements were reduction of noise and improvement of reproducibility, and adoption of a floating circuit. Further, the ECM amplifier was connected to personal computer for storage of data. Repeated measurements on the same sample indicated good reproducibility.","subitem_description_type":"Other"}]},"item_1_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15094/00008943","subitem_identifier_reg_type":"JaLC"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00181831","subitem_source_identifier_type":"NCID"}]},"item_1_source_id_20":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00857289","subitem_source_identifier_type":"ISSN"}]},"item_1_subject_19":{"attribute_name":"米国議会図書館件名標目表","attribute_value_mlt":[{"subitem_subject":"62(*2)","subitem_subject_scheme":"LCSH"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Institute of Low Temperature Science, Hokkaido University"},{"subitem_text_language":"en","subitem_text_value":"Institute of Low Temperature Science, Hokkaido University"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"北海道大学低温科学研究所"},{"subitem_text_value":"北海道大学低温科学研究所"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1996-11-01"}],"displaytype":"detail","filename":"KJ00000140279.pdf","filesize":[{"value":"270.7 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"KJ00000140279","url":"https://nipr.repo.nii.ac.jp/record/8943/files/KJ00000140279.pdf"},"version_id":"c5fa3134-7cf1-4b66-9ed5-2ce2842bcc87"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"氷床コア解析のためのECM増幅器の改良とデータ処理","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"氷床コア解析のためのECM増幅器の改良とデータ処理"},{"subitem_title":"Development of high-performance amplifier of ECM-system for ice core analysis and data management","subitem_title_language":"en"}]},"item_type_id":"1","owner":"4","path":["1115"],"pubdate":{"attribute_name":"公開日","attribute_value":"1996-11-01"},"publish_date":"1996-11-01","publish_status":"0","recid":"8943","relation_version_is_last":true,"title":["氷床コア解析のためのECM増幅器の改良とデータ処理"],"weko_creator_id":"4","weko_shared_id":4},"updated":"2023-07-25T13:12:46.019788+00:00"}