{"created":"2023-07-25T11:03:27.546981+00:00","id":6354,"links":{},"metadata":{"_buckets":{"deposit":"603aeb31-2f33-4b5f-b854-1b566bcb1987"},"_deposit":{"created_by":4,"id":"6354","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"6354"},"status":"published"},"_oai":{"id":"oai:nipr.repo.nii.ac.jp:00006354","sets":["1259:1260:1261:802:806"]},"author_link":["18257","4777","44791","7751","7720","44793"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"156","bibliographicPageStart":"146","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"Advances in polar upper atmosphere research"}]}]},"item_1_creator_8":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shiokawa, Kazuo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Katoh, Yasuo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Satoh, Mitsugi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ogawa, Tadahiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Taguchi, Makoto","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamagishi, Hisao","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"This paper reports the performance and capability of a newly developed zenith spectrometer (for measurements of airglow and aurora) that uses an acousto-optic tunable filter (AOTF). The AOTF can scan the pass-band of the spectrometer between 450 and 700 nm with a bandwidth of 2-3 nm by changing the RF driver frequency from 180 to 100 MHz. The absolute sensitivity of the spectrometer is ~0.1-1.5 counts/Rayleigh/s per spectral step. The spectrometer is fully automated. The O I (557.7 nm) airglow line can be clearly identified in test observations of midlatitude airglow performed at Shigaraki Observatory, Japan. Based on an estimate of the signal-to-noise ratio, we conclude that the full auroral spectrum (450-700) nm can be measured by the AOTF spectrometer with a time resolution of ~100 s and a signal-to-noise ratio of ~100 for an auroral emission intensity of 10 kR. An example of the auroral spectra is shown for observations made at Syowa Station in Antarctica.","subitem_description_type":"Other"}]},"item_1_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15094/00006354","subitem_identifier_reg_type":"JaLC"}]},"item_1_publisher_22":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"National Institute of Polar Research"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA11397422","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Solar-Terrestrial Environment Laboratory, Nagoya University/Solar-Terrestrial Environment Laboratory, Nagoya University/Solar-Terrestrial Environment Laboratory, Nagoya University/Solar-Terrestrial Environment Laboratory, Nagoya University/National Institute of Polar Research/National Institute of Polar Research"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2002-09-01"}],"displaytype":"detail","filename":"KJ00000047993.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"KJ00000047993","url":"https://nipr.repo.nii.ac.jp/record/6354/files/KJ00000047993.pdf"},"version_id":"f138945c-a65f-41e5-b1fe-8f3785c36e42"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"New auroral spectrometer using an acousto-optic tunable filter","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"New auroral spectrometer using an acousto-optic tunable filter"}]},"item_type_id":"1","owner":"4","path":["806"],"pubdate":{"attribute_name":"公開日","attribute_value":"2002-09-01"},"publish_date":"2002-09-01","publish_status":"0","recid":"6354","relation_version_is_last":true,"title":["New auroral spectrometer using an acousto-optic tunable filter"],"weko_creator_id":"4","weko_shared_id":4},"updated":"2023-07-25T12:02:38.054291+00:00"}