{"created":"2023-07-25T11:01:13.048434+00:00","id":3149,"links":{},"metadata":{"_buckets":{"deposit":"84ac8f3e-7571-4130-841c-5c9f10530038"},"_deposit":{"created_by":4,"id":"3149","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"3149"},"status":"published"},"_oai":{"id":"oai:nipr.repo.nii.ac.jp:00003149","sets":["1259:1260:1265:435:443"]},"author_link":["14994","220","57255","17428","66002"],"item_1_alternative_title_5":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_alternative_title":"Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica"}]},"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"57","bibliographicPageStart":"49","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"Polar geoscience"}]}]},"item_1_creator_8":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ikeda, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Doi, Koichiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Fukuda, Yoichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamura, Yoshiaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shibuya, Kazuo","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"During the wintering period of the 44th Japanese Antarctic Research Expedition (JARE-44: February 2003 to January 2004), a new superconducting gravimeter CT(#043) with a cryocooler was installed and tested to replace the former TT70(#016) at Syowa Station, Antarctica. The CT(#043) has design sensitivity of 1nGal (1×10^(-11)m/s^2) to study the Earth's dynamics in tidal and longer-period bands. A new type of diaphragm was used to effectively isolate the vibration from the refrigerator cold-head and to prevent solid air contamination from entering the Dewar. A real-time remote monitoring system including a Web camera for diagnostics from Japan has also been installed.","subitem_description_type":"Other"}]},"item_1_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15094/00003149","subitem_identifier_reg_type":"JaLC"}]},"item_1_publisher_22":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"National Institute of Polar Research"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA1130866X","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Research Facility Center for Science and Technology Cryogenics Division,University of Tsukuba"},{"subitem_text_language":"en","subitem_text_value":"National Institute of Polar Research"},{"subitem_text_language":"en","subitem_text_value":"Department of Geophysics, Graduate School of Science, Kyoto University"},{"subitem_text_language":"en","subitem_text_value":"National Astronomical Observatory of Japan"},{"subitem_text_language":"en","subitem_text_value":"National Institute of Polar Research"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2005-10-01"}],"displaytype":"detail","filename":"KJ00003562990.pdf","filesize":[{"value":"3.3 MB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"KJ00003562990","url":"https://nipr.repo.nii.ac.jp/record/3149/files/KJ00003562990.pdf"},"version_id":"735cdae1-e357-42d9-8cf8-89cdffc6fe36"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"superconducting gravimeter","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"GM refrigerator","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"diaphragm","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"monitoring system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Syowa Station","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica"}]},"item_type_id":"1","owner":"4","path":["443"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-10-01"},"publish_date":"2005-10-01","publish_status":"0","recid":"3149","relation_version_is_last":true,"title":["Installation of the superconducting gravimeter CT(#043) at Syowa Station, Antarctica"],"weko_creator_id":"4","weko_shared_id":4},"updated":"2023-07-25T12:34:25.392056+00:00"}