{"created":"2023-07-25T11:01:12.981854+00:00","id":3148,"links":{},"metadata":{"_buckets":{"deposit":"2719a476-9200-4424-99ec-bb0b36cad2e2"},"_deposit":{"created_by":4,"id":"3148","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"3148"},"status":"published"},"_oai":{"id":"oai:nipr.repo.nii.ac.jp:00003148","sets":["1259:1260:1265:435:443"]},"author_link":["14994","4456","17428","43305","66002"],"item_1_alternative_title_5":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_alternative_title":"Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica"}]},"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"48","bibliographicPageStart":"41","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"Polar geoscience"}]}]},"item_1_creator_8":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Fukuda, Yoichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Iwano, Sachiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ikeda, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hiraoka, Yoshifumi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Doi, Koichiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"For the purpose of calibration of the superconducting gravimeter (SG) model CT#043 at Syowa Station, Antarctica, we carried out parallel observations with the absolute gravimeter (AG) FG5#210. Although the AG measurements were conducted from December 31, 2003 to February 9, 2004, SG measurements before January 17 are found to have suffered artificial sensitivity change. We finally adopted data from January 17 to February 1, 2004, and obtained the scale factor of CT#043 as -59.461 ±0.079μGal/volt by linear regression analysis. The result achieved a relative accuracy of around 0.1%, which is important to modern precise tidal analysis. We also determined the scale factor by comparing the data of parallel observations with the SG TT70#016. Both values showed good agreement, supporting the reliability of the above mentioned value.","subitem_description_type":"Other"}]},"item_1_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15094/00003148","subitem_identifier_reg_type":"JaLC"}]},"item_1_publisher_22":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"National Institute of Polar Research"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA1130866X","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Geophysics, Graduate School of Science, Kyoto University"},{"subitem_text_language":"en","subitem_text_value":"Department of Geophysics, Graduate School of Science, Kyoto University"},{"subitem_text_language":"en","subitem_text_value":"Cryogenics Division, Research Facility Center, University of Tsukuba"},{"subitem_text_language":"en","subitem_text_value":"Geographical Survey Institute"},{"subitem_text_language":"en","subitem_text_value":"National Institute of Polar Research"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2005-10-01"}],"displaytype":"detail","filename":"KJ00003562984.pdf","filesize":[{"value":"906.8 kB"}],"format":"application/pdf","licensetype":"license_6","mimetype":"application/pdf","url":{"label":"KJ00003562984","url":"https://nipr.repo.nii.ac.jp/record/3148/files/KJ00003562984.pdf"},"version_id":"e27e39fe-97f3-44f0-839e-b238ace0d234"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"superconducting gravimeter","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"scale factor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"calibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"absolute gravity measurements","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica"}]},"item_type_id":"1","owner":"4","path":["443"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-10-01"},"publish_date":"2005-10-01","publish_status":"0","recid":"3148","relation_version_is_last":true,"title":["Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica"],"weko_creator_id":"4","weko_shared_id":4},"updated":"2023-07-25T12:34:26.825318+00:00"}