WEKO3
アイテム
{"_buckets": {"deposit": "6542932b-e9d1-400e-ba2f-1eee5b10329b"}, "_deposit": {"created_by": 4, "id": "3645", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "3645"}, "status": "published"}, "_oai": {"id": "oai:nipr.repo.nii.ac.jp:00003645", "sets": ["528"]}, "author_link": ["5280", "5281", "5279"], "item_1_alternative_title_5": {"attribute_name": "論文名よみ", "attribute_value_mlt": [{"subitem_alternative_title": "APPLICATION OF THE DIELECTRIC PROFILING TECHNIQUE TO ICE CORE STUDIES"}]}, "item_1_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1991-05", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "92", "bibliographicPageStart": "81", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the NIPR Symposium on Polar Meteorology and Glaciology"}]}]}, "item_1_creator_7": {"attribute_name": "著者名よみ", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "/ マエノ, ノリカズ"}], "nameIdentifiers": [{"nameIdentifier": "5279", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_creator_8": {"attribute_name": "著者名(英)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "MOORE, John", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5280", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MAENO, Norikazu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "5281", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_type": "Other"}]}, "item_1_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "The dielectric profiling (DEP) technique is described and some of the differences between it and standard electrical tools used in ice core analysis are discussed. The results of DEP analysis on two cores from different regions of Antarctica, Dolleman Island and Mizuho Station are described. DEP measurements on the Dolleman core are related to the chemical composition of the core, showing that DEP can provide a high accuracy measure of total ionic content of the ice. The measurements on the Mizuho core are compared with earlier dielectric measurements on the same core which show dramatic changes over the 15 year period between the measurements. A mechanism which can explain the changes and other effects noted from d. c. conductivity (ECM) experiments, is suggested. The mechanism is based on the theory of d. c. conduction via liquid acid veins at triple junctions in the ice.", "subitem_description_type": "Other"}]}, "item_1_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.15094/00003645", "subitem_identifier_reg_type": "JaLC"}]}, "item_1_publisher_22": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "National Institute of Polar Research"}]}, "item_1_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10756213", "subitem_source_identifier_type": "NCID"}]}, "item_1_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Institute of Low Temperature Science, Hokkaido University:(Present address) British Antarctic Survey, Natural Environment Research Council"}, {"subitem_text_language": "en", "subitem_text_value": "Institute of Low Temperature Science, Hokkaido University"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "1991-05-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00000767848.pdf", "filesize": [{"value": "1.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_6", "mimetype": "application/pdf", "size": 1900000.0, "url": {"label": "KJ00000767848", "url": "https://nipr.repo.nii.ac.jp/record/3645/files/KJ00000767848.pdf"}, "version_id": "68095bc6-c885-4086-8ec4-ba91bfa3a4b4"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "APPLICATION OF THE DIELECTRIC PROFILING TECHNIQUE TO ICE CORE STUDIES", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "APPLICATION OF THE DIELECTRIC PROFILING TECHNIQUE TO ICE CORE STUDIES"}]}, "item_type_id": "1", "owner": "4", "path": ["528"], "permalink_uri": "https://doi.org/10.15094/00003645", "pubdate": {"attribute_name": "公開日", "attribute_value": "1991-05-01"}, "publish_date": "1991-05-01", "publish_status": "0", "recid": "3645", "relation": {}, "relation_version_is_last": true, "title": ["APPLICATION OF THE DIELECTRIC PROFILING TECHNIQUE TO ICE CORE STUDIES"], "weko_shared_id": 4}
APPLICATION OF THE DIELECTRIC PROFILING TECHNIQUE TO ICE CORE STUDIES
https://doi.org/10.15094/00003645
https://doi.org/10.15094/00003645012224c3-f562-4ece-be52-262376a61625
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00000767848 (1.9 MB)
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1991-05-01 | |||||
タイトル | ||||||
タイトル | APPLICATION OF THE DIELECTRIC PROFILING TECHNIQUE TO ICE CORE STUDIES | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.15094/00003645 | |||||
ID登録タイプ | JaLC | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
論文名よみ | ||||||
その他のタイトル | APPLICATION OF THE DIELECTRIC PROFILING TECHNIQUE TO ICE CORE STUDIES | |||||
著者名よみ |
/ マエノ, ノリカズ
× / マエノ, ノリカズ |
|||||
著者名(英) |
MOORE, John
× MOORE, John× MAENO, Norikazu |
|||||
著者所属(英) | ||||||
en | ||||||
Institute of Low Temperature Science, Hokkaido University:(Present address) British Antarctic Survey, Natural Environment Research Council | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Low Temperature Science, Hokkaido University | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The dielectric profiling (DEP) technique is described and some of the differences between it and standard electrical tools used in ice core analysis are discussed. The results of DEP analysis on two cores from different regions of Antarctica, Dolleman Island and Mizuho Station are described. DEP measurements on the Dolleman core are related to the chemical composition of the core, showing that DEP can provide a high accuracy measure of total ionic content of the ice. The measurements on the Mizuho core are compared with earlier dielectric measurements on the same core which show dramatic changes over the 15 year period between the measurements. A mechanism which can explain the changes and other effects noted from d. c. conductivity (ECM) experiments, is suggested. The mechanism is based on the theory of d. c. conduction via liquid acid veins at triple junctions in the ice. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10756213 | |||||
書誌情報 |
Proceedings of the NIPR Symposium on Polar Meteorology and Glaciology 巻 4, p. 81-92, 発行日 1991-05 |
|||||
出版者 | ||||||
出版者 | National Institute of Polar Research |