{"_buckets": {"deposit": "e5ecc6a6-c102-48d8-8e4b-a201410c4f2f"}, "_deposit": {"created_by": 4, "id": "23", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "23"}, "status": "published"}, "_oai": {"id": "oai:nipr.repo.nii.ac.jp:00000023", "sets": ["11"]}, "author_link": ["65665"], "item_1_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1979-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "57", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "Memoirs of National Institute of Polar Research. Ser. F, Logistics"}]}]}, "item_1_creator_8": {"attribute_name": "著者名(英)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Awano, Seiiti", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "65665", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_type": "Other"}]}, "item_1_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "\"A new axial-flow wind air-turbine NU-102 having an external diameter of 1.2 m was developed in 1977 by the authors for harnessing the energy of high speed winds in Antarctica. This multi-blade wind-turbine is featured by the presence of a stator before the rotor, which enables the turbine to give a higher power, a higher torque at a lower rotational speed than an ordinary wind air-turbine. A 3-kW AC-DC generator is driven by the air-turbine through a planetary speed-up gear of speed ratio 6. The rotational speed of this generator can automatically be kept at a desired value even in violent blizzards by means of an electric eddy-current brake newly developed by the authors. The brake also affords a new means for converting the wind energy directly into heat through the liquid heated in the jacket of the brake-stator. The present report describes the design of the whole system, the general perormance of the air-turbine, and the combined performance of the wind-turbine and generator evaluated in wind-tunnel tests and field tests at Syowa Station. The field tests have proved that a generator output of 2.4 kW can be obtained at a wind velocity of 30 m/s, and that the rotational speed of the generator can be kept at a desired value for variable loads and wind velocities exceeding 30 m/s.\"", "subitem_description_type": "Other"}]}, "item_1_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA0073354X", "subitem_source_identifier_type": "NCID"}]}, "item_1_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "College of Science and Technology, Nihon University"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "1979-10-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00000011429.pdf", "filesize": [{"value": "10.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_6", "mimetype": "application/pdf", "size": 10700000.0, "url": {"label": "KJ00000011429", "url": "https://nipr.repo.nii.ac.jp/record/23/files/KJ00000011429.pdf"}, "version_id": "74c757b0-0c76-4fd5-a449-59e6d7e5355a"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Axial Flow Wind Air -Turbine NU-102 with Electric Eddy-Current Brake", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Axial Flow Wind Air -Turbine NU-102 with Electric Eddy-Current Brake", "subitem_title_language": "en"}]}, "item_type_id": "1", "owner": "4", "path": ["11"], "permalink_uri": "https://nipr.repo.nii.ac.jp/records/23", "pubdate": {"attribute_name": "公開日", "attribute_value": "1979-10-01"}, "publish_date": "1979-10-01", "publish_status": "0", "recid": "23", "relation": {}, "relation_version_is_last": true, "title": ["Axial Flow Wind Air -Turbine NU-102 with Electric Eddy-Current Brake"], "weko_shared_id": 4}
Axial Flow Wind Air -Turbine NU-102 with Electric Eddy-Current Brake
https://nipr.repo.nii.ac.jp/records/23
https://nipr.repo.nii.ac.jp/records/23cddaaf88-9601-441c-9b7d-d71a0ae037ef
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00000011429 (10.7 MB)
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1979-10-01 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Axial Flow Wind Air -Turbine NU-102 with Electric Eddy-Current Brake | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
著者名(英) |
Awano, Seiiti
× Awano, Seiiti |
|||||
著者所属(英) | ||||||
en | ||||||
College of Science and Technology, Nihon University | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | "A new axial-flow wind air-turbine NU-102 having an external diameter of 1.2 m was developed in 1977 by the authors for harnessing the energy of high speed winds in Antarctica. This multi-blade wind-turbine is featured by the presence of a stator before the rotor, which enables the turbine to give a higher power, a higher torque at a lower rotational speed than an ordinary wind air-turbine. A 3-kW AC-DC generator is driven by the air-turbine through a planetary speed-up gear of speed ratio 6. The rotational speed of this generator can automatically be kept at a desired value even in violent blizzards by means of an electric eddy-current brake newly developed by the authors. The brake also affords a new means for converting the wind energy directly into heat through the liquid heated in the jacket of the brake-stator. The present report describes the design of the whole system, the general perormance of the air-turbine, and the combined performance of the wind-turbine and generator evaluated in wind-tunnel tests and field tests at Syowa Station. The field tests have proved that a generator output of 2.4 kW can be obtained at a wind velocity of 30 m/s, and that the rotational speed of the generator can be kept at a desired value for variable loads and wind velocities exceeding 30 m/s." | |||||