WEKO3
アイテム
{"_buckets": {"deposit": "8089c705-4ee4-473a-ac4c-f6842681a9fa"}, "_deposit": {"created_by": 26, "id": "16334", "owners": [26], "pid": {"revision_id": 0, "type": "depid", "value": "16334"}, "status": "published"}, "_oai": {"id": "oai:nipr.repo.nii.ac.jp:00016334", "sets": ["2042"]}, "author_link": ["71852", "71853", "71851"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-12", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "100570", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{}, {"bibliographic_title": "Polar Science", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Calibration of optical instruments is important for accurate measurement of the absolute emission intensity of aurora and airglow. The National Institute of Polar Research (NIPR), Japan, has been operating a facility for the optical calibration which consists of three independent calibration systems to share with collaborating researchers. This paper introduces an outline of the facility and specifications of each system, calibration procedures, and examples of calibration results. With this facility, we can obtain the calibration data for the absolute sensitivity of optical instruments with an accuracy of about 2% within a wavelength range between 420 and 1050 nm. In addition, it is possible to calibrate transmission of optical filters and also relative sensitivity of optical instruments as a function of wavelengths. Current facility, upgraded in 2012, has been used by many researchers to calibrate their various optical instruments.", "subitem_description_type": "Abstract"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1016/j.polar.2020.100570"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.polar.2020.100570", "subitem_relation_type_select": "DOI"}}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18739652", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ogawa, Y.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "71851", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kadokura, A.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "71852", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ejiri, M.K.", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "71853", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Aurora", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Airglow", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Calibration", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Integrating sphere", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Monochromator", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Optical calibration system of NIPR for aurora and airglow observations", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optical calibration system of NIPR for aurora and airglow observations"}, {"subitem_title": "Optical calibration system of NIPR for aurora and airglow observations", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "26", "path": ["2042"], "permalink_uri": "https://nipr.repo.nii.ac.jp/records/16334", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-11-26"}, "publish_date": "2020-11-26", "publish_status": "0", "recid": "16334", "relation": {}, "relation_version_is_last": true, "title": ["Optical calibration system of NIPR for aurora and airglow observations"], "weko_shared_id": -1}
Optical calibration system of NIPR for aurora and airglow observations
https://nipr.repo.nii.ac.jp/records/16334
https://nipr.repo.nii.ac.jp/records/16334fdf40117-137e-4f81-a1e2-ce18fd5fc2d6
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-11-26 | |||||
タイトル | ||||||
タイトル | Optical calibration system of NIPR for aurora and airglow observations | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Optical calibration system of NIPR for aurora and airglow observations | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Aurora | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Airglow | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Calibration | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Integrating sphere | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Monochromator | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ogawa, Y.
× Ogawa, Y.× Kadokura, A.× Ejiri, M.K. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Calibration of optical instruments is important for accurate measurement of the absolute emission intensity of aurora and airglow. The National Institute of Polar Research (NIPR), Japan, has been operating a facility for the optical calibration which consists of three independent calibration systems to share with collaborating researchers. This paper introduces an outline of the facility and specifications of each system, calibration procedures, and examples of calibration results. With this facility, we can obtain the calibration data for the absolute sensitivity of optical instruments with an accuracy of about 2% within a wavelength range between 420 and 1050 nm. In addition, it is possible to calibrate transmission of optical filters and also relative sensitivity of optical instruments as a function of wavelengths. Current facility, upgraded in 2012, has been used by many researchers to calibrate their various optical instruments. | |||||
書誌情報 |
en : Polar Science 巻 26, p. 100570, 発行日 2020-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 18739652 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.polar.2020.100570 | |||||
関連名称 | 10.1016/j.polar.2020.100570 |