Water Research Institute, Nagoya University
Water Research Institute, Nagoya University
Water Research Institute, Nagoya University
抄録(英)
Water vapor content was measured by a balloon-borne hygrometer (Lyman-alpha/OH fluorescence type) at Syowa Station (69°00'S, 39°35'E), Antarctica on October 27,1983. The result showed a very dry air of about 1 ppmv just above the tropopause. This may be a consequence of the active "freeze-out" of water from the Antarctic stratosphere because of its coldness in winter.
雑誌書誌ID
AA00733561
雑誌名
Memoirs of National Institute of Polar Research. Special issue